Input | Phase | Three-phase three-wire + ground wire |
Voltage | 220V ±10% | |
Frequency | 50/60Hz±5Hz | |
AC output | Phase | Three-phase four-wire + ground wire, transformer isolated output |
Rated voltage | 115.0V(LN) | |
Voltage adjustment range | 10V-150.0V(LN) | |
Voltage regulation resolution | 0.1V | |
Rated frequency | 400.0Hz | |
Adjustment amplitude | 0.1Hz | |
Frequency stability | ≤±0.0 1 % | |
Total harmonic content | ≤2% ( Linear load) ( FS ) | |
Waveform | Sine Wave | |
Display device |
show | 7-inch color LCD touch screen |
Output phase voltage | Resolution 0.1V, Accuracy: ±(0.2 % reading + (±0.3 % range) | |
Output frequency | Resolution 0.1Hz, Accuracy: ±0.02% reading | |
Output current | Resolution 0.1A, Accuracy: ±(0.5% reading + (±0.5% range) | |
Output power | Resolution 0.1KW, Accuracy: ± (0.5% reading + (± 0.5% range) | |
Efficiency | ≥85% | |
Communication interface | RS232 communication Modbus RTU protocol | |
Protection function | Output, over-current, over-voltage, under-voltage, short-circuit, over-load, over-heat protection ; | |
Dielectric strength | Input, output to housing: AC1500V/1min, leakage current <20mA | |
Insulation resistance | Input, output to housing: ≥20M (DC500V) | |
Usage environment | Temperature: -20ºC~45ºC Humidity: 10%~90% (25ºC, no condensation)Sea wave height ≤2000m |