Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | AZY-1115 | |
Capacity | 15 kVA | |
Dimension | 51*63*25mm | |
Weight | 65kg | |
Input | Voltage | 1 Phase 2 Wire: 220V± 10% (option *) |
Frequency | 50 Hz or 60 Hz ± 5% | |
Output | Voltage, current | 110V Setting (Low grade): 0-150V, 125A |
220V Setting 0-300V (High grade): 0-300V, 62.5A | ||
Load stabilization Rate | ≤±1% | |
Frequency | 50Hz, 60Hz up to 400Hz adjustable Note: -When the output is 400Hz, the load capacity can only reach 50% of the rated capacity. -When the output is ≤120Hz, the load capacity can reach 100% of the rated value. -You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option. |
|
Frequency Stability | ≤±0.01% | |
Harmonic Distortion | Pure Sine Wave ≤2% | |
Frequency meter | 4 digit, digital frequency meter, resolution 0.1Hz/Step | |
Voltmeter | 4 digit, digital voltage meter, resolution 0.1V | |
Ammeter | 4 digit, digital ammeter, resolution 0.1A | |
Watt meter | 4 digit, digital Watt meter, resolution 0.1W | |
Protection | With overload, short circuit, over temperature | |
Instantaneous power failure protection and alarm device | ||
Working Environment | Temperature | 0 - 40 deg.ºC |
Humidity | 0 - 90% (Non condensation) |
Model (IPS-FC61) | 61005 | 6101 | 6102 | 6103 | 6105 | 6106 | 6110 | 6115 | ||
Output capacity (KVA) | 0.5 | 1 | 2 | 3 | 5 | 6 | 10 | 15 | ||
Rated power output(KW) | 0.4 | 0.8 | 1.6 | 2.4 | 4 | 4.8 | 8 | 12 | ||
Circuit mode | IGBT/SPWM | |||||||||
AC input | Single-phase 220V/50Hz or 60Hz | |||||||||
AC output | Output Phase | Single-phase 220V | ||||||||
Voltage | Low range | 0~150V Adjustable | ||||||||
High range | 0~300V adjustable | |||||||||
Frequency | 40~499.9HZ can be setting by software | |||||||||
Max current | low-grade | 4.2A | 8.4 A | 17 A | 25 A | 42 A | 50 A | 84 A | 125 A | |
high-grade | 2.1 A | 4.2 A | 8.4 A | 12.5 | 21 A | 25 A | 42 A | 63 A | ||
Frequency stability rate | Frequency stability rate | |||||||||
Load voltage stabilizing rate | Load voltage stabilizing rate | |||||||||
Waveform distortion degree | Waveform distortion degree | |||||||||
Response time | Response time | |||||||||
Indication resolution | Digit frequency | 4 digits display, resolution 0.1Hz | ||||||||
Digit voltage | 4 digits virtual value display, resolution 0.1V | |||||||||
Digit current | 4 digits virtual value display, resolution 0.01A | |||||||||
Digit power | 4 digits virtual value display, resolution 1W | |||||||||
Protection | overvoltage, over current, overload, over temperature and short-circuit, as well as automatic jump protection and alarm device | |||||||||
Cooling | Forced fan cooling | |||||||||
Working temperature | 0ºC~45ºC, | |||||||||
Environment humidity | Relative 0~90%( non-coagulation state ) | |||||||||
Product Dimension(cm) | 43*18*44 | 43*18*47 | 43*65*52 | 55*74*52 | ||||||
Net weight (kg) | 26 | 32 | 37 | 48 | 63 | 80 | 145 | 175 |
Model (IPS-FC62) | 6220 | 6230 | 6245 | 6260 | 62100 | 62120 | 621150 | 62200 | ||
Output capacity (KVA) | 20 | 30 | 45 | 60 | 100 | 120 | 150 | 200 | ||
Rated power output(KW) | 16 | 24 | 36 | 48 | 80 | 96 | 120 | 160 | ||
Circuit mode | IGBT/SPWM | |||||||||
AC input | Tri-phase 220V/50Hz or 60Hz | |||||||||
AC output | Output Phase | 3-phases 380V | ||||||||
Voltage | Low range | 0~150V Adjustable | ||||||||
High range | 0~300V adjustable | |||||||||
Frequency | 40~499.9HZ can be setting by software | |||||||||
Max current | low-grade | 168A | 250 A | 375 A | 500 A | 834 A | 1000 A | 1250 A | 1667 A | |
high-grade | 84 A | 125 A | 188 A | 250 A | 417 A | 500 A | 625 A | 834 A | ||
Frequency stability rate | Frequency stability rate | |||||||||
Load voltage stabilizing rate | Load voltage stabilizing rate | |||||||||
Waveform distortion degree | Waveform distortion degree | |||||||||
Response time | Response time | |||||||||
Indication resolution | Digit frequency | 4 digits display, resolution 0.1Hz | ||||||||
Digit voltage | 4 digits virtual value display, resolution 0.1V | |||||||||
Digit current | 4 digits virtual value display, resolution 0.01A | |||||||||
Digit power | 4 digits virtual value display, resolution 1W | |||||||||
Protection | overvoltage, over current, overload, over temperature and short-circuit, as well as automatic jump protection and alarm device | |||||||||
Cooling | Forced fan cooling | |||||||||
Working temperature | 0ºC~45ºC, | |||||||||
Environment humidity | Relative 0~90%( non-coagulation state ) | |||||||||
Product Dimension(cm) | 58*74*52 | 70*120*110 | 80*120*150 | 100*150*160 | ||||||
Net weight (kg) | 285 | 385 | 420 | 560 | 960 | 1150 | 1450 | 1900 |
Model IPS-FC63 |
6303 | 6306 | 6310 | 6315 | 6320 | 6330 | 6345 | 6360 | 63100 | 63120 | 63400 | 63500 | 63600 |
Rated Capacity (KVA) | 3 | 6 | 10 | 15 | 20 | 30 | 45 | 60 | 100 | 120 | 400 | 500 | 600 |
Phase Capacity (KVA) | 1 | 2 | 3.3 | 5 | 7 | 10 | 15 | 20 | 33 | 40 | 134 | 167 | 200 |
AC Input | Single phase 220V/50Hz,60Hz | Tri phase 380V/50Hz,60Hz | |||||||||||
AC Output | |||||||||||||
Phase | Trip phase (phase difference 120°±2°) | ||||||||||||
Output Frequency | 40~499.9HZ can be setting by software | ||||||||||||
AC Voltage Output | |||||||||||||
Low Range | Phase voltage:0V~150V (line voltage:0V~260V) | ||||||||||||
High Range | Phase voltage:0V~300V (line voltage:0V~520V) | ||||||||||||
Max Current output | |||||||||||||
0~150V | 8.4A | 16.8A | 28A | 42A | 50A | 84A | 125A | 168A | 276A | 336A | 1112A | 1400A | 1667A |
0~300V | 4.2A | 8.4A | 14A | 21A | 25A | 42A | 63A | 84A | 138A | 168A | 556A | 700A | 833A |
Frequency Stability Rate | ≤±0. 1% | ||||||||||||
Load Stability Rate | ±0.5% | ||||||||||||
Waveform Distortion | ≤±2%(resistance load) | ||||||||||||
Response Time | ≤2ms | ||||||||||||
Indication Resolution | |||||||||||||
Digit Frequency | 4 digit resolution 0.1Hz | A,B,C phase can change optionally |
|||||||||||
Digit Voltage | 4 digit resolution 0.1V | ||||||||||||
Digit Current | 4 digit resolution: below 4A:0.001A; above 4A:0.01A | ||||||||||||
Digit Power | 4 digit resolution 1W | ||||||||||||
Protection | Input no fuse switch, output fuse switch, electronics circuit speed detect the over voltage, over current, over load, over temperature, short circuit and automatic jump protection and alarm. |
||||||||||||
Cooling | Forced fan cooling | ||||||||||||
Environment | |||||||||||||
Operation Temperature | 0ºC~45ºC | ||||||||||||
Relative Humility | 0~90%(non condensing ) | ||||||||||||
Working Temperature | 0ºC~45ºC, Relative 0~90%( non-coagulation state ) | ||||||||||||
Shape | |||||||||||||
Dimensions (MM) | 190* 305* 430 |
280* 450* 500 |
620* 320* 620 |
950* 560* 650 |
700* 1340* 1280 |
1700* 1750* 1000 |
1650* 850* 1090 |
1650* 800* 1200 |
|||||
Weight(Kg) | 30 | 35 | 45 | 60 | 78 | 140 | 170 | 280 | 650 | 1050 | 1250 | 1350 | 1450 |
Model | 68005 | 6801 | 6802 | 6803 | 6805 | 6810 | 6815 | 6820 | 6830 | 6845 | 6860 | 68100 | |
Rated Capacity (KVA) |
500 | 1 | 2 | 3 | 5 | 10 | 15 | 20 | 30 | 45 | 60 | 100 | |
Circuit Mode | IGBT/PWM | ||||||||||||
AC Input | Single-phase 220V/50Hz,60Hz | Tri-phase 380V/50Hz,60Hz | |||||||||||
AC Output | |||||||||||||
AC Output | Phase | Single phase | |||||||||||
Voltage | Low Range | 0V~150V | |||||||||||
Low Range | 0V~300V | ||||||||||||
Frequency | 40~499.9HZ can be setting by software | ||||||||||||
Max Current | 0V-150V | 4.2A | 8.4A | 16.8A | 25A | 42A | 84A | 126A | 168A | 250A | 375A | 500A | 834A |
0V-300V | 2.1A | 4.2A | 8.4A | 12.5A | 21A | 42A | 63A | 84A | 125A | 188A | 250A | 417A | |
Frequency Stability Rate | ≤±0.1% | ||||||||||||
Load Stability Rate | ±0.5% | ||||||||||||
Waveform Distortion | ≤2%(linear load) | ||||||||||||
Respond Time | Max 2ms | ||||||||||||
Indication Resolution | |||||||||||||
Digit Frequency | 4 digit resolution 0.1Hz | ||||||||||||
Digit Voltage | 4 digit resolution 0.1V | ||||||||||||
Digit Current | 4 digit resolution below 4A:0.001A above 4A:0.01A | ||||||||||||
Digit Power | 4 digit resolution below 200W:0.1W above 200W:1W | ||||||||||||
Digit Frequency | 4 digit resolution 0.001 | ||||||||||||
Protector | Input no fuse switch, output fuse switch, electronics circuit speed detect the over voltage, over current, over load, over temperature, short circuit and automatic jump protection and alarm. | ||||||||||||
Cooling | Forced fan cooling | ||||||||||||
Environment | |||||||||||||
Operate Temperature | 0ºC~45ºC | ||||||||||||
Related Humility | 0~90%(non condensing ) | ||||||||||||
Dimension H*W*D(mm) | 187*428*440 | 650*430*520 | 900*450*710 | 900*560*710 | 1200*560*800 | 1200*850*1020 | 1600*800*1200 |
Phase number | Single-phase | Three-phase | |
Capacity | 500VA-45KVA | 3KVA-400KVA | |
Production method | IGBT / PWM pulse width modulation mode | ||
Input | Voltage (optional) | 1-Phase 2-wire + G:110V(2-5KVA) , 200V/230V/240Z±10% | |
Output | 3-phase 4-wire + G:Y connection 190/110,200/115.208/120,220/128,230/132,240/139V±10% | ||
3-phase 4-wire + G: Y connection:380/220,400/230,415/240,400/254,460/265.480/277V±10% | |||
3-phase 3-wire + G: delta connection:220,230,240,380,400,415,440V±10% | |||
Frequency (optional) | 40~499.9HZ can be setting by software | ||
Voltage | 110V system:0-150V(Low Range) | Options: 1. 0-600v; 2. Standard setting voltage: ± 10% ~ + 25%, - 10% -- 30% preset | |
220V system:0-300V(High Range) | |||
Load stability rate | ≤±1% | ||
Frequency | Frequency 40.0hz to 1990.9hz (programmable) | ||
Frequency stability | ≤±0.01% | ||
Harmonic distortion | Sine wave, ≤2% | ||
Frequency table | 4-digit, digital frequency meter, resolution 0.1hz/step | ||
Voltmeter | 4-digit, digital voltmeter, resolution 0.1V | ||
Ammeter | 4-digit, digital ammeter, resolution 0.1A | ||
Wattmeter | 4-digit, digital wattmeter, resolution 0.1W | ||
Protector | It has overload, over high temperature, short circuit, instantaneous power-off protection and alarm device | ||
Temperature | Temperature: 0-40deg. ºC | ||
Work environment | 0.90% (noncondensing state) |
1 | Home appliances | 8 | Photovoltaic |
2 | Motors | 9 | Lamps |
3 | Power tools | 10 | Electronic transformers |
4 | Switching power supplies | 11 | Electronic components |
5 | Power adapters | 12 | Low-voltage distribution |
6 | UPS | 13 | Power |
7 | Information and communication | 14 | Other industries |